U.S. ROBOTICS, INC. DIRECT 2400PC Modem Type Data (synchronous/asynchronous) Maximum Data Rate 2400bps Data Bus 8-bit ISA Data Modulation Unidentified Protocol [Image] CONNECTIONS Purpose Location Purpose Location Line out CN1 Volume SW2 Line in CN2 DTR SIGNAL Setting SW1/1 » On DTR forced high Off DTR normal RESULT CODES Setting SW1/2 » Off Verbose result codes enabled On Numeric result codes enabled RESULT CODES DISPLAY Setting SW1/3 » On Display enabled Off Display disabled ECHO COMMANDS DISPLAY Setting SW1/4 » Off Local echo enabled On Local echo disabled AUTO ANSWER Setting SW1/5 » On Modem does not answer on first ring Off Modem answers on first ring CARRIER DETECT Setting SW1/6 » Off CD normal On CD forced high MULTI-LINE INSTALLATION Setting SW1/7 » Off Single phone connected On Multiple phones connected AT COMMAND SET Setting SW1/8 » On AT command set enabled Off AT command set disabled ESCAPE CODE Setting SW1/9 » On Go to command mode and display OK result code when escape character is received Off Disconnect, go to command mode and display NO CARRIER when escape character is received FACORY CONFIGURED SETTINGS Switch Setting SW1/10 Off BASE I/O ADDRESS SELECTION Address J1 J2 COM1: (3F8h) Pins 1 & 2 closed Pins 1 & 2 closed COM2: (2F8h) Pins 2 & 3 closed Pins 1 & 2 closed COM3: (3E8h) Pins 1 & 2 closed Pins 2 & 3 closed COM4: (2E8h) Pins 2 & 3 closed Pins 2 & 3 closed INTERRUPT IRQ J5 3 Pins 3 & 5 closed 4 Pins 1 & 3 closed 5 Pins 2 & 4 closed 7 Pins 4 & 7 closed Proprietary AT Command Set See document V1255 for a full command summary.